Determination and analysis of the stresses in a flange Charnley hip prosthesis

K. D. Tzileridis

Determination and analysis of the stresses in a flange Charnley hip prosthesis

by K. D. Tzileridis

  • 94 Want to read
  • 16 Currently reading

Published by UMIST in Manchester .
Written in English


Edition Notes

StatementSupervised by: McLeish, R.D..
ContributionsMcLeish, R. D., Supervisor., Mechanical Engineering (A.M.).
ID Numbers
Open LibraryOL19657288M

The prosthesis should be inserted in varus position with regard to the axis of the intramedullary canal, and the prosthesis should be made of an alloy with appreciably higher yield stress and fatigue strength than the alloys of the investigated broken Charnley and Charnley-Müller type by: The concept of a cementless “isoelastic” hip stem was reportedly conceived in by Robert Mathys as an alternative to the cemented metallic hip implant design developed by Sir John Charnley,. The isoelastic hip stem was intended to replicate the stiffness of the femur, to reduce stress shielding, and improve implant : Judd Day, Judd Day, Steven M. Kurtz, Steven M. Kurtz, Kevin Ong.

normal stress (pressure) and shear stress at the interface between the prosthesis and the limb. The measurement and display of this three-dimensional stress profile in time present an interesting engineering evaluation with' definite physiological implications. Other instrumentation and data reduction. Fig. 1: Simple scheme of stress shielding (Surin, ) stress shiel(ing by taking the ratio of maximum bone stress that occur in implanted femur to the reference implant. The location where stress shielding occurs can also be determined in finite element model as shown in Fig. 2 (Swanson et al., ). The analysis compared the stress.

Full text of "Early development of total hip replacement: the transcript of a Witness Seminar held by the Wellcome Trust Centre for the History of Medicine at UCL, London, on 14 March " See other formats. Abstract. The main long-term problem with total hip arthroplasty remains aseptic loosening, particularly of the cup. This was pointed out by Charnley in [31] and is demonstrated by the survivorship analyses of Sutherland et al. [], Morscher and Schmassmann [], and others (Fig. 1).Cited by: 4.


Share this book
You might also like
Appetizers and beverages from Santa Fe kitchens

Appetizers and beverages from Santa Fe kitchens

Chemical inhibition method for lactate dehydrogenase isoenzyme 1

Chemical inhibition method for lactate dehydrogenase isoenzyme 1

Proposed resource management plan and final environmental impact statement

Proposed resource management plan and final environmental impact statement

Real Estate Mortgage Taxes.

Real Estate Mortgage Taxes.

How to Lose Weight

How to Lose Weight

Accidental Innocence

Accidental Innocence

ALGEBRA TRIG SCHOOL TEXT

ALGEBRA TRIG SCHOOL TEXT

The Army Rangers

The Army Rangers

Information Technology in Education Research Programme 1988-93.

Information Technology in Education Research Programme 1988-93.

The British music trade.

The British music trade.

Determination and analysis of the stresses in a flange Charnley hip prosthesis by K. D. Tzileridis Download PDF EPUB FB2

Stress shielding, a mechanical phenomenon that refers to the reduction of load transferred to the surrounding bone, is one of the possible factors to cause bone resorption. After insertion of the implant into the intramedullary canal, the load transferred to the bone could change if the load was partially absorbed by the prosthesis, which in turn would decrease the stress distributed at the bone–implant interface.

Shielding of the bone from stress results Cited by: 7. Charnley, J.: Stainless steel for femoral hip prostheses in combination with a high density polythene socket. Journal of Bone and Joint Surgery 53 B, () Google Scholar by: An experimental analysis of the stresses at the surface of Charnley hip prostheses zero angle between its neck axis and the original femoral neck axis.

After the distal third of the femora were removed, the cut ends were cast with acrylic cement into a 36 mm inner diameter pipe Cited by: 9.

INTRODUCTION The analysis of stress in the femur where there is an implant is an important aspect of the design of the femoral components of the total hip prosthesis. Calculations by Charnley () showed that the use of cement between bone and prosthesis greatly reduced the stresses to which the bone was exposed McLeish and Haboobi () used electrical resistance strain gauges to measure surface by: of finite element stress analysis of the system formed by the skeleton and hip prosthesis during two-legged standing.

The main focus is on the calculation of the stresses in the pelvic. The analysis of anatomical specimens and considerations on optimisation show, however, that the bending theory of the proximal femur gives still the best explanation for the observations. Charnley total hip replacement was designed princip- ally to minimize the shear stresses at the cement–bone interface through the action of a small femoral head.

We analysed 68 cases of acetabular augmentation using the Wroblewski wedge for recurrent posterior dislocation of Charnley total hip replacements inserted through a posterior approach. model of the implanted proximal femur to examine stresses behaviors in cemented hip arthroplasty with different tapered design of prosthesis.

The calculated stress distribution is discussed with respect to stress shielding and bone remodeling issues in THR femur case. The taper of the prosthesis. Finite element analysis showed that the maximum von Mises stress occurred at the head region of the hip prosthesis.

By analyzing the maximum von Mises stress and directional and unidirectional deformation of the model are shown in the table 2. The stresses on the total hip replacement interfaces were then determined via finite element analysis and the findings compared with the strength values obtained from the mechanical tests.

The Effect of Prosthesis Orientation on’ stress-Shielding’ using Finite Element Analysis — Indications as to Bone Remodeling Prendergast P.J., Taylor D., A Stress Analysis of the Proximo-Medial femur after Total Hip Gentz C-F., Mechanical Looseninf of the Femoral Head Prosthesis in Charnley Total Hip Arthroplasty, Clin., Orthop Author: P.

Prendergast, B. McCormack, T. Gunawardhana, D. Taylor. that the self-heating testing allows rapid determination of fatigue properties of an annealed bar of Titanium alloy Ti6Al4V used to forge hip prosthesis.

Since these first, highly promising results, we have evaluated the method on various raw materials used to forge hip prosthesis [11,12]. The femoral component of the artificial hip joint implanted in a patient's femur is subjected to a complex set of forces exerted due to normal life activities.

It is thought that high values of stress in the cement in a cemented prosthesis can lead to fractures of the cement mantle and loosening of the by: Finite element model required for FE analysis was created by discretizing the geometric (i.e.

CAD) model shown in Fig. 1 into smaller and simpler elements. The FEM model of the prosthesis consists of to four-node tetrahedron elements; 48, elements for femur, 13, elements for bone–cement elements for the by: This paper presents a finite element analysis regarding the stress distribution in a cemented Austin Moore type hip prosthesis.

The 3-D model was obtained using a Roland PICZA 3-D laser scanner. The applied loads simulate the normal gait cycle. The prosthesis is made from stainless steel with a femoral head of 45mm diameter. The numerical analysis was performed using the ABAQUS : Lucian Bogdan, Cristian Sorin Nes, Nicolae Faur, Mihaela Amarandei, Angelica Enkelhardt.

Material Characterization and Stress Analysis of a Through Knee Prosthesis Sockets Mohsin Abdullah Al-Shammari1, Emad Q. Hussein2, control forces by the hip operating in a physiological condition muscles and the muscles themselves are for the most part intact.

AbstractThe aim of this work was to study how the stress distributions of the hip joint’s components were changed if the activity was switched from walking to stair climbing for three different prostheses types subjected to either concentrated or distributed load. In the scope of the study, three different cemented prostheses, namely, Charnley, Muller, and Hipokrat were used for cemented Cited by: 3.

Figure 10 Prosthesis in position. [27] Figure 12 Charnley prosthesis used to replace damaged hip joint. [29] 21 Materials of Components Stem The main requirements of a material for the stem of a hip prosthesis are high strength, high hardness and high toughness.

STRESSES IN THE NORMAL PELVIS V. GOEL*, S. VALLIAPPANt and N. SVENSSON$ The University of New South Wales, Kensington, N.S.W. Australia (Received 9 August ; in revised form 11 March ) Abstract-This paper deals in the stresses in the hip bone as a result of the forces in the muscles and ligaments acting on by:.

The paper present the analysis of metal prosthesis head stress state of hip joint endoprosthesis which is a result of variable loads during human motor activity and its influence on the erosion of materials. The analysis of stress state was made with use of FEM – ADINA numerical tool.

The analysis of surface erosion process was made with use of the scanning electron by: 3. Finite element model of the cemented hip prosthesis. Charnley cemented hip joint is modeled in this analysis. The geometry of the model was taken from a real femoral bone with a higher degree of accuracy.

The left femur of an old man was selected for modeling. Nine contiguous longitudinal CT scan slices were obtained using a GE Research Author: H.S. Hedia, N. Fouda.prosthesis made of this relatively ductile and resistant material, still wears. Figure 1: Hip joint prosthesis Parts of the hip prosthesis The anatomic hip prosthesis may be cemented and cementless depending on the type of fixation used to hold the implant in place.

Construction: socket; - metal head; - metal stem of different types.